Autonomous Crack Measurement (ACM) facilitates simultaneous measurement of crack response to environmental changes and vibrations produced by various construction activities. Dual-purpose crack displacement sensors measure crack response, while the vibration environment is defined by standard seismological transducers and the weather environment is defined as changes in temperature and humidity. This...
All structures have cosmetic cracks, which have no influence on structural integrity and usually remain unremarked until the structure’s occupants sense ground vibrations. Such vibrations are often associated with engineering activity, but are rarely responsible for cracks. However, this is difficult to prove without scientific basis. Automated Crack Monitoring (ACM)...
Micro-meter dynamic crack responses in a two story structure to rock blasting- and wind gust- excitation are compared to those induced by long term climatological effects. These measurements substantiate the conservancy of the 12.5 mm/s (0.5 in./s) blasting vibration control to protect residential structures against cracking. The test structure was...