This appendix synthesizes micrometer changes in crack width in response to both long term (environmental) and transient (blast vibration) of four of the structures in the main body. The appendix begins with a description of the genesis of the study and instruments employed. Response of the distressed wood-framed structure in...
Autonomous Crack Measurement (ACM) facilitates simultaneous measurement of crack response to environmental changes and vibrations produced by various construction activities. Dual-purpose crack displacement sensors measure crack response, while the vibration environment is defined by standard seismological transducers and the weather environment is defined as changes in temperature and humidity. This...
All structures have cosmetic cracks, which have no influence on structural integrity and usually remain unremarked until the structure’s occupants sense ground vibrations. Such vibrations are often associated with engineering activity, but are rarely responsible for cracks. However, this is difficult to prove without scientific basis. Automated Crack Monitoring (ACM)...
Cosmetic cracks are very common in structures, and most of the time they remain unnoticed and do not decrease the structural integrity. Although these cracks are unremarkable and barely noticeable, occupants become concerned about these cracks when construction occurs nearby. In order to investigate the true nature of these cracks,...
In early 2001, a sinkhole formed directly under State Road 66 near the city of Sebring in Highlands County, Florida. The Florida DOT built a land bridge over the sinkhole and the road was reopened to traffic. Since SR-66 is an important regional trucking route, it was decided that the...
Crack and structural response to construction trench blasting was measured in a woodframe house with a stucco exterior. Blasts at distances between 232 m to 368 m produced peak particle velocities (PPV) and air blast over pressures (AB) of 9 mm/sec and 0.02 kPa (123 dB), respectively. Structural response velocities...
This thesis summarizes two further developments of the Autonomous Crack Monitoring (ACM) system, which facilitates simultaneous measurement of crack response to environmental changes and various dynamic events. The first component was measurement of crack responses in three different materials and locations in a residential structure subjected to ground vibrations produced...
This thesis summarized the qualification and testing of two commercial Autonomous Crack Monitoring (ACM) systems for use in measuring micrometer displacement of cracks. Qualification involved the assessment of both laboratory and field performance in a residential structure subjected to nearby quarry blasting for the production of roadway aggregate. Aggregate and...
A unique judicial opportunity allowed measurement of the response of three cracks in residential structure to blasting for underground aggregate mining. Instrumented cracks were located in the interior basement CMU mortar and upstairs dry wall as well as exterior brick work. The dynamic environment was unusual. Even though the blasting...
Micro-meter dynamic crack responses in a two story structure to rock blasting- and wind gust- excitation are compared to those induced by long term climatological effects. These measurements substantiate the conservancy of the 12.5 mm/s (0.5 in./s) blasting vibration control to protect residential structures against cracking. The test structure was...