Despite a relatively mature technology for its control, corrosion caused by stray current from electrified rapid-transit systems costs the United States approximately $500 million annually. Part of that cost is the result of corrosion of the electrified rapid-transit system itself, and part is the result of corrosion on neighboring infrastructure...
The finite element method is used to investigate failure mechanisms in pin-hanger connection in aging highway bridges. Bridge pins and hangers are typically considered as critical elements whose failure may result in partial or entire collapse of the structure. The primary function of a pin-hanger connection is to allow for...
Current bridge condition determination is based almost entirely on the use of visual inspection. This approach to bridge inspection provides data that is subjective and not traceable. Nondestructive evaluation (NDE) is a tool that in actuality is little used on bridges, but could eliminate much of the subjectivity of the...
This report includes the findings of acoustic emission (AE) tests on the Fremont tied arch bridge in Portland Oregon conducted by research engineers from the Infrastructure Technology Institute of Northwestern University on March 24th, 1997.