This report shows the results of acoustic emission (AE) monitoring, and provides additional information on the nature of the ultrasonic indications in the north east trunnion shaft.
A remote global monitoring system is being operated on a 65 year old lift bridge in Sturgeon Bay Wisconsin. The system uses both strain gages and clinometers to continuously monitor the "health" of the fracture critical components of the bridge. Ruggedized miniaturized data loggers are locally mounted on the structure...
Current bridge condition determination is based almost entirely on the use of visual inspection. This approach to bridge inspection provides data that is subjective and not traceable. Nondestructive evaluation (NDE) is a tool that in actuality is little used on bridges, but could eliminate much of the subjectivity of the...
This technical report shows the findings of acoustic emission and strain gage monitoring tests conducted by research engineers of Infrastructure Technology Institute from Northwestern University on April 18, 1997 in Sacramento, California.
This report includes the findings of acoustic emission (AE) tests on the Fremont tied arch bridge in Portland Oregon conducted by research engineers from the Infrastructure Technology Institute of Northwestern University on March 24th, 1997.
Acoustic emission (AE) testing was used to identify the source of audible “bangs” generated during opening and closing of a large, double-leaf rolling-lift bascule bridge. The data were analyzed using a combination of well-established AE
techniques, including first hit analysis (FHA), planar location analysis, and linear location analysis. The FHA...