This paper describes the technology and methods deployed in the continuous autonomous remote monitoring of cracks in interior and exterior walls of a residence near a limestone quarry. The object is to quantitatively compare crack response to blast-induced ground motion to that induced by diurnal temperature changes, weather fronts, and...
The concrete currently used in the slip-form paving process is a low slump concrete that requires both internal and external vibration in order to achieve satisfactory compaction. The use of vibrator fingers for the internal vibration often leads to trails on the surface of the pavement and to segregation around...
Successful use of monitoring data to update performance predictions of supported excavations depends equally on reasonable numerical simulations of performance, the type of monitoring data used as observations, and the inverse analysis techniques used to minimize the difference between predictions and observed performance. This paper summarizes each of these factors...
Two numerical procedures are described that quantitatively identify a set of constitutive parameters that best represents observed ground movement data associated with a deep excavations in urban environments. This inverse problem is solved by minimizing an objective (or error) function of the weighted least-squares type that contains the difference between...
This paper describes qualification of devices to measure sub micro-meter changes in crack width, which is the basis of autonomous crack monitoring for control of blasting vibrations. Performance of LVDT, eddy current and potentiometer sensors to monitor long-term and transient displacements will be described. Potentiometers are attractive for wireless measurement,...
A unique judicial opportunity allowed measurement of the response of three cracks in residential structure to blasting for underground aggregate mining. Instrumented cracks were located in the interior basement CMU mortar and upstairs dry wall as well as exterior brick work. The dynamic environment was unusual. Even though the blasting...
Micro-meter dynamic crack responses in a two story structure to rock blasting- and wind gust- excitation are compared to those induced by long term climatological effects. These measurements substantiate the conservancy of the 12.5 mm/s (0.5 in./s) blasting vibration control to protect residential structures against cracking. The test structure was...
The paper deals with the behavior of fluid cement pastes, formulated from Self Consolidating Concretes (SCCs), and the experimental correlation of fundamental rheological properties, such as the yield stress and the viscosity, with measurements from field tests, such as the mini-cone slump flow test. As a matter of fact, several...